The copper core conductor has excellent conductivity, PVC insulation and sheath for double protection, moisture-proof and wear-resistant, with high mechanical strength; light structure, flexible laying, suitable for fixed wiring; temperature resistant to 70°C, electrical safety and stability, easy installation and maintenance, moderate cost, widely used in building lighting, power lines, strong practicality.
Lightweight PVC sheathed cable 60227 IEC 10 (BVV) is a building wire, which is implemented in accordance with GB/T 5023.4 and has a rated voltage of 300/500V. The cable consists of a copper core conductor, a PVC insulation layer and a light PVC sheath, and has excellent conductivity, insulation performance and corrosion resistance.
I. Product Features
1. Rated voltage: U0/U (phase voltage/line voltage) is 300/500V, suitable for electrical devices, instruments, telecommunications equipment, power lighting and other lines with AC rated voltage of 300/500V and below or DC voltage of 750V and below.
2. Conductor DC resistance: meets the requirements of GB/T 3956-2008 to ensure efficient power transmission.
3. Insulation resistance: has good insulation performance to ensure power safety.
4. Power frequency AC withstand voltage test: the cable is immersed in 20℃ water for one hour, and the insulation does not break down after the voltage is applied, meeting the safety requirements.
5. Laying temperature: should not be lower than 0℃ to ensure the normal use of the cable.
6. Bending radius: The allowable bending radius of cables with an outer diameter (D) less than 25mm should not be less than 4D, and the allowable bending radius of cables with an outer diameter (D) of 25mm and above should not be less than 6D, which is convenient for construction and installation.
2. Product use
Lightweight polyvinyl chloride sheathed cable 60227 IEC 10 (BVV) is suitable for fixed laying of power units with an AC rated voltage of 450/750V and below. It is widely used in home decoration, factories, communication base stations and other fields to provide power support for electrical equipment.
3. Product specifications
This product has a variety of specifications, and the nominal cross-section of the conductor ranges from 1.5mm² to 35mm². The appropriate specifications can be selected according to actual needs. At the same time, the product also provides detailed technical parameters and performance indicators to meet the needs of different users.
4. Precautions
1. During use, the cable should be protected from excessive mechanical stress and extrusion to avoid damage to the cable structure.
2. The cable should be stored in a dry, ventilated environment without corrosive gases to avoid moisture and corrosion.
3. The installation should be carried out in accordance with relevant specifications to ensure the safe and reliable use of the cable.