The advantages of polyvinyl chloride (PVC) insulated cables include: resistance to acid and alkali corrosion, good flame retardancy, flexibility and easy laying, low cost and stable insulation. They are suitable for low-voltage distribution systems below 70°C, but attention should be paid to the release of hydrogen chloride gas during combustion.
Cable products using polyvinyl chloride (PVC) as the insulating material.
This type of cable possesses excellent electrical performance, mechanical properties, and chemical corrosion resistance, and is widely used in power transmission, electrical equipment, construction, and other fields.
Its insulation layer is made of PVC material, which can effectively insulate electric current and ensure the safety and stability of the cable during use.
PVC insulated cables also have good heat resistance, cold resistance, and aging resistance, enabling long-term use in various harsh environments.
This product is manufactured in accordance with GB/T 5023-2008 "Polyvinyl Chloride Insulated Cables with Rated Voltage up to 450/750V" and JB/T 8734-2016 "Polyvinyl Chloride Insulated Wires, Cables and Flexible Wires with Rated Voltage up to 450/750V".
Model | Name | Standard |
60277 IEC 01 (BV) | Single-core Rigid Conductor Non-sheathed Cable for General Purposes | |
60277 IEC 02 (RV) | Single-core Flexible Conductor Non-sheathed Cable for General Purposes | |
Lightweight Polyvinyl Chloride Sheathed Cable | ||
60277 IEC 10 (BVV) | GB/T 5023-2008 | |
60277 IEC 52 (RVV) | Lightweight Polyvinyl Chloride Sheathed Flexible Wire | |
60277 IEC 53 (RVV) | General Polyvinyl Chloride Sheathed Flexible Wire | |
BLVV | Aluminum-core Polyvinyl Chloride Insulated and Sheathed Round Cable | |
BV | Copper-core Polyvinyl Chloride Insulated Wire | |
BLV | Aluminum-core Polyvinyl Chloride Insulated Wire | |
BVR | Copper-core Polyvinyl Chloride Insulated Flexible Cable | |
BVV | Copper-core Polyvinyl Chloride Insulated and Sheathed Round Cable | |
BVVB | Copper-core Polyvinyl Chloride Insulated and Sheathed Flat Cable | JB/T 8734-2016 |
BLVVB | Aluminum-core Polyvinyl Chloride Insulated and Sheathed Flat Cable | |
RVS | Copper-core Polyvinyl Chloride Insulated Twisted Flexible Wire for Connection | |
RVV | Copper-core Polyvinyl Chloride Insulated and Sheathed Flexible Cable | |
RVB | Copper-core Polyvinyl Chloride Insulated Fan-shaped Non-sheathed Flexible Wire | |
RVVP | Copper-core Polyvinyl Chloride Insulated and Sheathed Flexible Wire |
Model | Rated Voltage | Number of Cores | Conductor Cross-section / mm² |
60277 IEC 01 (BV) | 450/750V | 1 | 1.5~185 |
60277 IEC 02 (RV) | 450/750V | 1 | 1.5~240 |
60277 IEC 1 (BVV) | 300/500V | 2~5 | 1.5~35 |
60277 IEC 52 (RVV) | 300/300V | 2~3 | 0.5~0.75 |
60277 IEC 53 (RVV) | 300/500V | 2~5 | 0.75~2.5 |
BV | 300/500V | 1 | 0.75~1.0 |
BLV | 450/750V | 1 | 2.5~400 |
BVR | 450/750V | 1 | 25~70 |
BVV | 300/500V | 1 | 0.75~185 |
BLVV | 300/500V | 1 | 2.5~185 |
BVVB | 300/500V | 2~3 | 0.75~10 |
BLVVB | 300/500V | 2~3 | 25~10 |
RVS | 300/300V | 2 | 0.5~6 |
RVV | 300/500V | 2~41 | 0.5~10 |
RVB | 300/300V | 2 | 0.5~6 |
RVVP | 300/300V | 2~3 | 0.5~1.5 |
The rated voltage U0 is 450/750V, 300/500V, and 300/300V.